MachinistCharts

Bolt torque and tightening

Bolt torque formula: T = K × F × d

Short answer

The bolt torque formula is T = K × F × d: torque equals the nut factor K times the clamp load F times the nominal diameter d. With K = 0.20 for dry steel and F = 75 % of proof load, an M10 class 8.8 bolt needs 50 N·m (37 ft-lb); oiled at K = 0.15 it needs 38 N·m.

By the MachinistCharts editors · Updated · 8 min read · Checked against ISO 898-1, SAE J429, ISO 724, ASME B1.1

Steel hex bolt, nut and washer next to a click torque wrench on a workbench

Key takeaways

  • Torque formula for bolts: T = K × F × d, and rearranged, F = T ÷ (K × d).
  • Nut factor K is about 0.20 dry, 0.22 zinc plated, 0.15 oiled and 0.10 to 0.12 with anti-seize.
  • Target clamp load F is usually 75 % of the bolt's proof load.
  • Torque is force times lever arm; the SI unit is N·m and 1 ft-lb = 1.3558 N·m.
  • Only about 10 % of tightening torque stretches the bolt; the rest is friction.

What is the bolt torque formula?

The bolt torque formula is T = K × F × d: tightening torque equals the nut factor K times the target clamp load F times the nominal bolt diameter d. It is the short-form torque equation used for nearly every bolt torque chart, including the charts on this site.

  • T is the tightening torque, in N·m when F is in kN and d is in mm, or in in-lb when F is in lbf and d is in inches.
  • K is the nut factor, a dimensionless number that lumps together thread friction, under-head friction and thread geometry. It is about 0.20 for dry steel and 0.15 for oiled threads.
  • F is the clamp load (preload) you want in the bolt. The usual target is 75 % of the bolt's proof load.
  • d is the nominal diameter: 10 mm for M10, 0.5 in for a 1/2-13 bolt.

Rearranged, the same equation gives clamp load from a known torque: F = T ÷ (K × d). Both directions are built into the bolt torque calculator.

The torque calculation formula is only as good as the K value. Change K from 0.20 to 0.15 and the torque for the same clamp load drops by 25 %. Change the lubricant without changing the torque and the clamp load rises by a third. That is why the thread condition is listed on every chart and why the bolt or equipment maker's specification always overrides a generic value.

What is torque? Meaning, symbol and units

Torque is a turning force: the force applied multiplied by the perpendicular distance from the axis of rotation. In equation form, torque = force × lever arm, or τ = r × F. Pull 100 N on a wrench handle 0.5 m from the bolt and you apply 50 N·m.

What is torque equal to?

Torque is equal to force times distance, measured at right angles to the line of the force. If the force is not perpendicular to the handle, only its perpendicular component counts: τ = r × F × sin θ, where θ is the angle between the handle and the force. At 90° the sine is 1 and you get the full value.

Torque symbol

Physics texts use the Greek letter τ (tau). Engineering standards and fastener charts usually write T, and German practice (VDI 2230) uses M for moment, as in MA for assembly torque. They all mean the same quantity.

Torque units

The SI unit is the newton metre (N·m). In the US, fastener torque is given in foot-pounds (ft-lb) for larger bolts and inch-pounds (in-lb) for small screws. Older metric drawings use kilogram-force metres (kgf·m).

FromToMultiply by
N·mft-lb0.7376
ft-lbN·m1.3558
ft-lbin-lb12
N·min-lb8.851
kgf·mN·m9.80665

For other units and force conversions (N, lbf, kgf), use the torque converter.

Torque and power: the power torque equation

For rotating machinery, power is torque times angular speed: P = T × ω, with ω in rad/s. In shop units, power in kW = torque in N·m × rpm ÷ 9549, and horsepower = torque in ft-lb × rpm ÷ 5252. This is the same torque, applied continuously instead of once to a fastener.

Nut factor K: dry vs lubricated vs plated vs anti-seize

The nut factor K is the number in the torque equation that accounts for friction. Use about 0.20 for dry plain steel, 0.22 for dry zinc plating, 0.15 for oiled threads and 0.10 to 0.12 for moly paste or anti-seize.

K is not a friction coefficient. It is an experimental constant measured on real joints, and it includes thread friction, friction under the nut or bolt head, and the small share of torque that actually stretches the bolt. A commonly cited approximate split is about 50 % of the input torque lost under the head, about 40 % lost in the threads, and only about 10 % producing preload.

The table below holds the clamp load constant at the 75 % target for an M10 class 8.8 bolt and shows how far the required torque moves with the thread condition.

Thread conditionTypical nut factor KM10 8.8 torque for 25.2 kNSame in ft-lb
Dry, plain (black oxide or bare) steel0.2050 N·m37 ft-lb
Zinc plated, dry0.2255 N·m41 ft-lb
Oiled threads and under head0.1538 N·m28 ft-lb
Moly paste or anti-seize0.1128 N·m20 ft-lb

The practical rule: if you lubricate a bolt, lower the torque. A lubricated or anti-seized bolt tightened to a dry torque figure is overloaded. With anti-seize at K 0.11, the dry M10 8.8 figure of 50 N·m would demand more clamp load than the bolt's proof load, so the bolt would yield.

Other things that move K: hot-dip galvanizing and rough or damaged threads raise it; reused bolts with burnished threads often lower it; thread-locking compounds act partly as a lubricant during tightening. Washers matter too, because most of the friction is under the head. A hardened washer gives a more repeatable bearing face than soft or painted material.

Bolt torque formula worked examples

Each example follows the same three steps: find the proof load, take 75 % of it as the clamp load, then apply T = K × F × d.

Example 1: M10 × 1.5, class 8.8, dry

  1. Tensile stress area: As = π/4 × (d − 0.9382 p)² = π/4 × (10 − 0.9382 × 1.5)² = 58.0 mm².
  2. Proof load: ISO 898-1 proof stress for class 8.8 at this size is 580 MPa, so the proof load is 580 × 58.0 = 33.6 kN.
  3. Clamp load: F = 0.75 × 33.6 = 25.2 kN.
  4. Torque: T = 0.20 × 25.2 kN × 10 mm = 50 N·m (37 ft-lb). Lubricated at K 0.15 it is 38 N·m.

Full figures for every class are on the M10 bolt torque page.

Example 2: M12 × 1.75, class 10.9, lubricated

As = 84.3 mm². Proof stress for 10.9 is 830 MPa, so the proof load is 69.9 kN and the clamp load is 52.5 kN. T = 0.15 × 52.5 × 12 = 94 N·m (70 ft-lb). Dry, the same bolt takes 126 N·m. See M12 bolt torque.

Example 3: 1/2-13 UNC, SAE grade 5, dry

Inch stress area: As = 0.7854 × (D − 0.9743 ÷ n)² = 0.7854 × (0.5 − 0.9743 ÷ 13)² = 0.1419 in². SAE J429 grade 5 proof strength is 85,000 psi, so the proof load is 12,061 lbf and the clamp load is 9,046 lbf. T = 0.20 × 9,046 × 0.5 = 905 in-lb, which is 75 ft-lb (102 N·m). See 1/2 inch bolt torque.

Example 4: from torque back to clamp load

An M10 8.8 bolt is oiled (K 0.15) but tightened to the dry figure of 50 N·m. F = T ÷ (K × d) = 50 ÷ (0.15 × 0.010 m) = 33.3 kN. That is 99 % of the 33.6 kN proof load instead of the intended 75 %. The bolt is at the edge of permanent stretch.

Bolt torque chart calculated from the formula

These values come straight from T = K × F × d with F = 75 % of proof load. Metric values use ISO 898-1 proof stress for class 8.8; inch values use SAE J429 grade 5 proof strength.

Metric class 8.8, coarse thread

BoltStress area AsClamp load F (75 % proof)Dry, K 0.20Lubricated, K 0.15
M6 × 120.1 mm²8.8 kN11 N·m (8 ft-lb)8 N·m (6 ft-lb)
M8 × 1.2536.6 mm²15.9 kN25 N·m (19 ft-lb)19 N·m (14 ft-lb)
M10 × 1.558.0 mm²25.2 kN50 N·m (37 ft-lb)38 N·m (28 ft-lb)
M12 × 1.7584.3 mm²36.7 kN88 N·m (65 ft-lb)66 N·m (49 ft-lb)
M16 × 2156.7 mm²68.2 kN218 N·m (161 ft-lb)164 N·m (121 ft-lb)
M20 × 2.5244.8 mm²110.2 kN441 N·m (325 ft-lb)330 N·m (244 ft-lb)
M24 × 3352.5 mm²158.6 kN761 N·m (562 ft-lb)571 N·m (421 ft-lb)

SAE grade 5, UNC thread

Bolt (UNC)Stress area AsClamp load F (75 % proof)Dry, K 0.20Lubricated, K 0.15
1/4-200.0318 in²2,029 lbf8 ft-lb (11 N·m)6 ft-lb (9 N·m)
5/16-180.0524 in²3,342 lbf17 ft-lb (24 N·m)13 ft-lb (18 N·m)
3/8-160.0775 in²4,940 lbf31 ft-lb (42 N·m)23 ft-lb (31 N·m)
1/2-130.1419 in²9,046 lbf75 ft-lb (102 N·m)57 ft-lb (77 N·m)
5/8-110.2260 in²14,408 lbf150 ft-lb (203 N·m)113 ft-lb (153 N·m)
3/4-100.3345 in²21,322 lbf267 ft-lb (361 N·m)200 ft-lb (271 N·m)

Other classes and sizes, including 10.9, 12.9 and grade 8, are on the main bolt torque chart. Bolt strength classes and head markings are explained in bolt grades and markings.

The long-form torque equation

The full torque equation splits K into its parts. In the VDI 2230 form it reads T = F × (0.16 × P + 0.58 × d2 × μG + Dkm ÷ 2 × μK), where P is the pitch, d2 the pitch diameter, μG the thread friction coefficient, Dkm the mean diameter of the bearing face under the head, and μK the under-head friction coefficient.

Worked through for an M10 × 1.5 bolt with a 16 mm hex, an 11 mm clearance hole and friction of 0.14 on both surfaces: d2 = 10 − 0.6495 × 1.5 = 9.026 mm and Dkm = (16 + 11) ÷ 2 = 13.5 mm. The bracket comes to 1.92 mm, so T = F × 1.92 mm. Dividing by d = 10 mm gives an equivalent K of 0.19, close to the 0.20 used for dry steel.

The pitch term, the only part that stretches the bolt, is just 13 % of the total. Everything else is friction. Engineers use the long form when friction coefficients are known from testing (ISO 16047); for general shop work the short formula with a sensible K is accurate enough.

When the torque formula is not enough

Torque is an indirect way to set clamp load, and the scatter in K typically gives ±25 % or more in actual preload. For critical joints, use a method that measures stretch or rotation instead.

  • Torque-angle: tighten to a snug torque, then turn a set number of degrees. Rotation is directly tied to bolt stretch, so friction matters less. See how to use a torque wrench.
  • Bolt elongation: measure stretch with a micrometer or ultrasonic gauge and convert to load.
  • Hydraulic tensioning: stretch the bolt directly, then run the nut down, with no torque friction involved.

How clamp load relates to joint behaviour, and why 75 % of proof is the usual target, is covered in bolt preload and clamp load. For flanges and covers, the order of tightening matters as much as the number: see bolt torque sequence. Tapped holes must also have enough thread engagement to carry the load; see thread engagement length.

Sources and standards

  • ISO 898-1, Mechanical properties of fasteners made of carbon steel and alloy steel
  • SAE J429, Mechanical and material requirements for externally threaded fasteners
  • ISO 724, ISO general-purpose metric screw threads, basic dimensions
  • ASME B1.1, Unified inch screw threads (UN and UNR thread form)
  • VDI 2230
  • ISO 16047

General reference information. When a manufacturer, drawing or governing standard gives a value, that value takes precedence.

Related charts and guides

Common questions

What is the formula for bolt torque?

Bolt torque is calculated with T = K × F × d, where K is the nut factor, F is the target clamp load and d is the nominal diameter. For an M10 class 8.8 bolt, F is 25.2 kN at 75 % of proof load, so with K = 0.20 the torque is about 50 N·m.

What is torque?

Torque is a turning force: force multiplied by the perpendicular distance from the axis of rotation. A 100 N pull on a wrench 0.5 m long gives 50 N·m. On a bolt, torque is the input that turns the nut and stretches the bolt to create clamp load.

What is torque equal to?

Torque is equal to force times lever arm length, measured at right angles to the force: τ = r × F × sin θ. When the force is perpendicular to the wrench, sin θ is 1 and torque is simply force times distance, for example 50 lbf at 1 ft equals 50 ft-lb.

What is the symbol for torque?

Physics uses the Greek letter τ (tau) for torque. Engineering drawings and fastener charts usually write T, and German standards such as VDI 2230 use M for moment. The SI unit is the newton metre, written N·m; US practice uses ft-lb and in-lb.

What K factor should I use for bolt torque?

Use about 0.20 for dry plain steel, 0.22 for dry zinc-plated bolts, 0.15 for oiled threads and 0.10 to 0.12 for moly paste or anti-seize. K varies by ±25 % or more between batches, so use the bolt or equipment maker's figure when one is given.

Does lubricating a bolt change the torque?

Yes. Lubrication lowers the nut factor from about 0.20 to 0.15, so the same clamp load needs about 25 % less torque. Applying a dry torque value to an oiled M10 8.8 bolt raises the clamp load to about 99 % of proof load, close to yielding the bolt.

What is the power torque equation?

Power equals torque times angular speed, P = T × ω. In shop units, kW = N·m × rpm ÷ 9549 and horsepower = ft-lb × rpm ÷ 5252. For example, 100 N·m at 3000 rpm is about 31 kW.

Arrow keys to move, Enter to open, Esc to close